Proliant dl360p gen8 fan noise Enjoy Free Shipping Worldwide! Limited Time Sale Easy Return. I bought 2x used HPDL360 ( no warrenty of support from HP) 2x 10Core Intel(R) Xeon(R) CPU E5-2660 v2 @ 2. Recently, I saw some people managing to control this issue HPE ProLiant DL360p Gen8 Server: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. The server is pretty loud. I had this happen recently on my DL360P Gen8, and it turned out that one of the fans was failing intermittently causing the others to spike up to 90%. Most often its bearing is noisy as well and then it surely needs replacement. Without realizing, a noisy factor was overlooked when purchasing and setting up the ProLiant DL360p Gen8 server. It's an HPE DL360p G8 with 2x Xeon 2620, 64GB RAM, 4x 100GB SSD and 4x 900GB HDD. The fan assembly is fully compatible with the HP Proliant DL360p Gen8 and DL360e Gen8 servers. Mar 30, 2004 · I have a second hand ML350p Gen 8 HP Proliant server which is too loud for my small office, even when all 4 fans are idling. 1) and because it was being quite noisey I had a look at the fan speeds. I run 2 SFF gen8's fully loaded, at idle they use about 80-110 watts. I took the opportunity to change my iLo ip address, it didn’t save or some reason. The intent of this document is to provide the details on the available cooling options and how to select/change the various options. These fans are very fast and very loud. In conclusion, the HPE DL360P Gen8 & DL360E Gen8 Hot Plug Fan Module with part number 667882-001 is an indispensable component for ensuring efficient cooling, extended hardware lifespan, and optimal performance in HPE DL360P Gen8 and DL360E Gen8 servers. 20GHz 2x 6Core Intel(R) TLDR: I installed the bios hack for that exposes fan commands to HP DL380 and it's ALMOST working. 78 to monitor one DL380 G9 In that server, 3 of 6 fans have become too loud especially fan#2 going 90-100% top speed. Great customer service. Yes I realize it's meant to be in a datacenter where noise doesn't matter, but I simply can't pass up a free server like this so I will do everything possible to make this happen without going crazy from noise. not sure why people say they are noisy, both of mine are really quiet with fans running 20-30%. The fan is still noisy. Replacing the fan resolved the issue. A short CPU stress test has no effect on CPU temperature or fan speed, power increases by 100 W. 17 of the HPE Broadcom NX1 Onlin Feb 20, 2022 · ilo4_unlock (Silence of the Fans) A toolkit for patching HPE's iLO 4 firmware with access to previously inaccessible utilities. HP iLO does not report fan speeds (among other things) when the server is off. This product also includes the locking latch. Jun 29, 2023 · Hello! I wanted to write an abbreviated guide for this, as controlling fan speed on this HPE box felt like quite the daunting task! This guide will apply to the majority of gen 8 and 9 HPE servers. Aug 19, 2022 · Hello everyone! I have an HPE Proliant G8 server which I use it for home labbing and also my desktop. In Stock. I knew how noisy it was having worked with it for years in our server room, however of course its intolerable in my home office. 96%. I read the words quiet and I see those 40mm dual fan things and struggle to believe. The CPU usage is almost zero what makes this difference. HPEサポートセンターのドキュメント表示ページです。 Heavy noise from 1U rack server (HP ProLiant DL320e Gen8 v2) I can not use in my homemore Jan 29, 2022 · Hey. I’ve run all the HP firmware updates on the server. I went to all of the trouble of upgrading I have (3) DL360p G8 servers mounted in a 25U open front and side rack in my office closet. The room is air conditioned and at 18digrees. 27K subscribers Subscribed Aug 31, 2023 · Change fan psu is very easy and reduce the noise. Mar 30, 2021 · About this item 【Compatibility】:This New replacement CPU cooling Server fan is Compatible for HP ProLiant DL360E DL360P G8 Gen8 Fan Module 667882-001 GFM0412SS Dec 13, 2020 · I’m playing with ESXi at home, on my test machine (HP Proliant DL360 gen9), and the fans are running 100% all the time… And is there a way to download BIOS upgrades for HP servers without a support agreement? Feb 20, 2022 · The server has trouble reading the temperature of non-HPE drives and spins up the fans as the result of an erroneous reading Bad airflow offers poor discharge of heat that causes fan spin up Replacing the fans with noise-efficient third party models would reduce the significance of the problem I'm having fan speeds and noise level issues from my most recent batch of HP ProLiant DL380 G7 servers. 5 U1 installed on the server and even when it is just sat idle with no real load on the server. 5 and openSUSE 13. As they stick a bit you modify the frame to allow for it. Fans at 19%, tested with various combinations of old non-HP SATA drives, it doesn’t matter if I insert 1 or 6 drives (without caddy). Apr 29, 2017 · I'm running ESXi on a HP DL380p Gen 8. Operates at 12V with a current of 1. 1, though the server is certifie Page 1 HPE ProLiant DL360p Gen8 Server Maintenance and Service Guide Abstract This guide describes identification and maintenance procedures, diagnostic tools, specifications, and requirements for hardware components and software. I would like to keep the stock fans thou. When 1 of the 8 redundant fans fail on an HPE Proliant Server, the rest will speed up to mach 10 speed to make up for the failed fan. 82A, providing powerful cooling for high-performance server environments. I have been tinkering with it, built a domain on it and such. " Two simultaneous fan failures will cause the system to shut down. I seem to luck out with my veeam-server. Apr 22, 2021 · About this item Fit Models : for HP ProLiant DL360p DL360e G8 Gen8 server P/N: 654752-001 667882-001 697183-001 You will receive: 1x Fan Ensure it is compatible with your model and check pictures for more details Apr 26, 2022 · The server reported 2 fans failed so I bought a whole new set and replaced the two that were failed. Any Jun 27, 2021 · When the server is powered off and is still plugged in, fan #6 only runs at almost full speed. Do I need any PCBs for fan installation? I also want to know the model of the "High-Performance Heatsink" that you used. Oct 29, 2025 · The Primary Zone Server (HP ProLiant DL360p Gen8) has a bad fan, and another fan fails intermittently. The DL360p G8 has proprietary fans, and will not boot if even a single one is missing. 4, but was not successful. Server is in power saver mode in both the bios and OS. I keep 20 spare fans on hand at my datacenter because of this. Using the custom iLO firmware you can manually tweak the fan speeds. As my username and password for iLo didn’t Sep 4, 2020 · The fans (654752-001) are ~$10 each. The Red wire to fan, cut and installed 2 x 22 Ohm 5W resistors in parallel but in series with the red wire supply. The second problem is related to the fans running consistently at the same speed regardless of the temperature. Specifically, firmware is patched with the ability to access new commands via SSH, relating to system health (h), fan tuning (fan), on-board temperature sensors (ocsd), and option chip health systems (ocbb). We would like to show you a description here but the site won’t allow us. Oct 18, 2021 · Ladies and Germs, I use ILO4 firmware 2. Up until a few weeks ago it has usually run relatively quiet with 5 drives and a Parity disk (6 total), but then the Parity HDD failed. I removed all the 16TB HDD comes with the server and install a single 2TB SATA SSD with adapter for my home lab. I’ve been planning to upgrade the CPUs and do some other tweaks, and finally got around to spending some time on the machine. One fan rotor failure will place server in degraded mode but fully functional. I tried to control the speed by ILO 3 in version 1. And if that doesn’t work try disabling secure boot. With big thanks to u/Vexamus; who a little while ago said to simply bridge pins 4-5-6 on the fan header and that should fool the HP server into believing the fans are still there and working. I haven't seen a good software solution under Ubuntu server to control the fan speed (the BIOS says that I'm already at the lowest cooling level, which is wild to me). Im thinking that it actually reset. 12 cm fan rear is more complicate and for example, with Noctua and Nvidia Tesla gpu HP Microserver Gen 8 power off because the fan not noise but haven´t high pressure and raise the temperatures with transcoding or any high work. At idle the server is loud, and if even a single logical core is under load then it's extremely loud. Jan 27, 2021 · Hp DL360 G8 fans noise after PCI (GPU) installation Ask Question Asked 4 years, 8 months ago Modified 1 year, 8 months ago Buy Server Cooling Fan for HP Proliant DL360P DL360e G8 Gen8 654752-001 667882-001 697183-001 697183-003 696154-002 732136-001 fans at Aliexpress for . Apr 22, 2019 · About this item 【Compatibility】This CPU replacement cooling fan is Compatible with ProLiant DL360E DL360P G8 Fan Module 654752-002 654752-003 667882-001 697183-002 697183-001 GFM0412SS 【Quality Item】All items are TESTED rigorously before shipping. computelabs. Very neat and professional modification. We bought an HP ProLiant DL320e Gen8 v2 server at office, to be used to run internal applications under Linux. My goal with these three servers is to run ESXi and vSAN with (8) SSDs in each server all while keeping the noise at a tolerable level ( <30% fan speed). Recently got myself a DL360 Gen8 and ran into this. This guide is for an experienced service technician. Mar 5, 2019 · I’ve had a DL360p Gen8 drop one fan one day and crank up the rpm on the remaining fans only to kill another one and hard shut-down before the 1st fan we ordered arrived. 0. Aug 26, 2020 · My experience is the opposite of many others. 1) has all fan speeds 3 days ago · HP 822531-001 - HP DL360 G8 Fan (Exact Part Number) The black HP fan is engineered specifically for the ProLiant DL360P and DL360E G8 servers, ensuring seamless compatibility and reliable performance in demanding enterprise environments. Without VMs, the rev-ups are more Buy Hpe 697183-001 Dual-rotor Enhanced Fan Assembly For Proliant Dl360p Gen8 Dl360e Gen8. Oct 14, 2014 · The HP ProLiant DL360p Gen8 Server is designed for large data centers that demand extensive compute density in addition to small and medium sized businesses that are looking to take advantage of the value, flexibility, and reliability of HP's Gen8 server platform. You can flip the BIOS option to allow operations with reduced fan count after you replace the fans. Upon startup, the server generates FAN noise for about 15 minutes. It would behoove you to replace the failed units. I have installed Windows server 2019 on it. It's replacing a small HP Microserver, which is near silent. 9. Here are the steps, although some are complex and I am linking to gui Jul 11, 2018 · The Fan in Slot 8 of my HP ProLiant DL360p Gen8 physically failed and the rest of my fans are running at 94%. I have an HP Proliant DL360p G8 1U rack server that I'm using to run Unraid with some dockers and such. I have noticed they are cheaper and less noisy when using windows server. Advisory: ProLiant Gen8 and Gen9 Servers Fans May Run at a High Speed After Updating The Adapter Firmware with Version 4. com FREE DELIVERY possible on eligible purchases May 24, 2014 · I’ve got a HP DL360 Gen8 that the fans just randomly spin up to max - the temperature in the room is only 21 degrees and I’ve had HP out to check the hardware and they say there’s no fault. The same server when formatted and installed win 2016 causes fan noise to increase slightly. So I have a hp proliant DL360p Gen8 that i bought from an old job. Most of the systems are nearly silent with low fan speeds (as reported by hplog -f). com FREE DELIVERY possible on eligible purchases Feb 15, 2025 · Hello, HP DL380 g9 server was running quiet fans with esxi 8 host. I want to replace fans with Noctua NF-A4x20 fans. The room temperature is 20c. @HP Oct 24, 2018 · F10 on boot at HP logo to get to BIOS on a Proliant. Esxi, proxmox etc seem to up the watts and fans. May 2, 2019 · Buy New Cooling Fan Compatible for HP ProLiant DL360 G8 DL360E G8 DL360P G8 Fan Module Part's Number 654752-002 654752-003 667882-001 697183-002 697183-001 GFM0412SS Fan: Laptop Replacement Parts - Amazon. It’s health led goes red and at SID over temp led goes yellow, and fans make a lot of noise, when I restarted the server. Server HPE ProLiant DL360p Gen8 Server: Access product support documents and manuals, software, download drivers by operating environment, and view product support videos. Before the Zone Controller (ZC) automatic switchover occurs, the server restarts. The HP ProLiant DL360p Gen8 Server comes with industry leading performance, efficiency, capacity, and reliability in a 1U space. Then try to disable the fan like suggested. Yesterday I was putting in some new SAS drives I ordered. Sep 29, 2019 · I have a HP PROLIANT DL360P Gen8 server. CPUs are idling. Whether you're enhancing an existing setup or replacing an old unit, this product guarantees seamless integration with your server architecture. 5" SATA drives - 4 in HP carriers, 4 in generic. now interested in exploring any settings that can be adjusted. (Yes, Im aware of the threads about fanmods). Apr 13, 2021 · Buy YEECHUN 2PCS DL360P G8 Fans, Fast Heat Dissipation Quiet CPU Cooling Fan Compatible with HP ProLiant DL360E G8 DL360 G8 Fans Module GFM0412SS 654752-002 654752-003 732136-001 697183-002 697183-003: CPU Cooling Fans - Amazon. co. Only thing running is the 2019 server core, without a single VM started. Apr 30, 2020 · Hi All, Wondering if anyone can help or at least point me in the right direction, i understand this is not an HP support forum, but i know mamy of your have experience. Is it possible to replace the fans for quieter alternatives? Or does someone have experience with 8 fan modules ship standard in 2 processor models The DL360p Gen8 will support up to 8 fans with fan redundancy built in. The following occurs when server fans fail: A common complaint about HP/HPE servers is that the fans are too loud when you add PCIe cards to the system. The majo Oct 2, 2020 · Hello, since months now, we have fan issues on our HPE DL380 Gen10. This causes the server to make an enormous amount of noise. The server has integrated P420i controller, which is known for running hot. The server provides enterprise-class design for performance workloads with versatile and future requirements, and it is ideal for performance-driven computing and storage in a dense rack package. I’ve got HP custom image of ESXi 5. On boot, the server’s fans went to 96% speed and stayed there. I know the server has this "sea of sensors" and it manages the fan speeds accordin HPE ProLiant DL360p G8 Gen8 Memory Spec Overview & Upgrade Tips | How to Configure the System HPE ProLiant MicroServer Gen10 Plus v Gen10 Hardware Differences Overview So I have the identical DL360 Gen9 Server which would SCREAM with fan noise, even when idle! Looked around for ways to quieten the fan noise, but in the meantime I had to upgrade the server from one CPU to two, memory from 48 to 96GB and add more fans. Feb 3, 2014 · Flashing amber system health LED according to HP means that the system is degraded in some way but in what way exactly? After adding non HP branded hard drives to the DL380 Gen 9 , the P840 raid controller (HBA Mode) could not read the HDD temperature sensors resulting in ramping up the fan speed to 100%. Cooling and ventilation have been adequately addressed, so I don't mind the noise if it is Dec 28, 2023 · A fluctuating fan would change its speed wildly, without any reason/temperature change. Nov 29, 2016 · Yesterday, I equipped a DL360p Gen8 with 8 consumer 2. Explore the four different thermal setting options of HPE iLO for fan control. but, once the server fully loads, the noise becomes tolerable. I'm wondering if replacing the fans with Noctua NF-A4x20 would be a worthwhile investment to quieten it to a more acceptable level. Find more , and products. Mar 19, 2021 · Hi! Im new to this forum but I have been reading on it for a while. DL360p Gen8 servers tend to lose these fans as they age. iLO flagged the 4 carriers as being non-HP. So far, I've managed to test with two fans and can confirm I get no errors at all while booting, but if I remove my little adapters it comes straight up with fan errors. Here is where this all starts to break down. Bypass HP ProLiant DL320e Gen8 system FAN failureuse a wire and place it on the yellow pines. I have set the bios option to Optimal Cooling and most of the times, the server is quite without any problem and rarely do the fans rev up! But some days That's 50% of what iLO nominated under the thermal (and no doubt hardware) circumstances. Maybe a short peak here and there. I have an ML350 Gen 9 myself. Anyone have any and can record some video with sound? Thanks. From what I Hp ProLiant DL360p Gen8 Pdf User Manuals. I run the HP Insight Diagnostic Test but no fault diagnos. com FREE DELIVERY possible on eligible purchases 822531-001: HP Dual Rotor Enhanced fan assembly for the Gen 8 HPE Proliant DL360p and DL360e server. Look up iLO4 fan control "the silence of the servers" Adds full manual control to g8/g9 fans, works very well with my dl320e g8v2, I found a docker container where someone wrote a webui that controls the fans with sliders. Has been going well for a month or so. I'll explain what I ended up doing with Fans 1 and 2 but for the unmodified Fan 3, I have applied a value of 40 to get it to about 30%, which is the optimal flow without the noise getting annoying for me. DL380e Gen8, 2x E5-2420, 32 GB, 6 fans, P420 controller, 2x750W PSU. It was a lot quieter than default and sounds like a solution for you, especially when you can set the minimum fan speed following this. Server has following specifications, Raid controller = P420i Two arrays 16 GB RAM The server is restarting after 8-10 min continuously. That is more of a problem. Two fan rotor failures could provide warning and imminent server shutdown. The average room temp is 73F How did you guys resolve this similar issue? please suggest troubleshooting tips that you had luck with in your environment. My basement is well insulated and the heat/noise is becoming too much with the gen8 servers. DL360p Gen8, with an extra Smart Array P822 PCIE-card and an HP Ethernet 10Gb 2-port 557SFP+ PCIE, yet my fans have never gone over 20%. The mod reduced noise like 4 aircraft taking off. Feb 25, 2018 · The fix to overcome the HP imposed issue was to modify the fan array, the 6 fans. After monitoring this for a while it seems that the G8 is running all fans at exactly the same speed not adjusting them individually to the temptreture zones they're designed to cool (attachment 1). Anyone know why this one fan would be running and at such high RPM (relative to powered on state)? Oct 7, 2018 · Im really intrested in the HP ProLiant DL380p Gen8 but its going to be in my room (a attic) and Im scared that its going to make too much noise for me to sleep. The intermittent failure of the second fan causes the server to automatically shut down the operating system. Im hoping that someone could help me understand why my fans are at such high percentage of speed. View online or download Hp ProLiant DL360p Gen8 User Manual, Specification Document Display | HPE Support CenterSupport Center Sep 30, 2019 · I have a HP PROLIANT DL360P Gen8 server. HPE ProLiant DL360p Gen8 Server Maintenance and Service Guide Abstract This guide describes identification and maintenance procedures, diagnostic tools, specifications, and requirements for hardware components and software. Our OS choice runs between CentOS 6. DL360 gen9 Noise Hi everyone! I'm in the market to upgrade from my stack of HPE gen8 servers to gen9. The server then immediately reported all fans failed so I tried replacing the other two and then Feb 26, 2013 · Hi there, I recently bought a DL360 G8 (running ESX 5. Can I get the fan speeds to slow down while I am in the process of replacing the failed fan? Expanding on the work of u/phoenixdev a while ago, I've developed a full toolkit for creating patched versions of HP's iLO4 firmware. I will first explain, what the problem is: The fans in the server irregularly spin up up to 100%, while the server is doing basically nothing. 1. replace a DL360p G8 FAN Oct 31, 2016 · Buy NEW HP Proliant DL360p DL360e G8 Server Cooling Fan 654752-001 / 667882-001: Case Fans - Amazon. Refurbished. CPUs are virtually bored. Designed to be housed within the server's computer case, this fan supports optimal thermal management, which is essential for maintaining system stability and Sep 1, 2025 · Designed specifically for HP Proliant DL360p, DL360e, and G8 Gen8 servers, ensuring optimal compatibility and performance. Certain HP ProLiant DL-series Gen8 servers may experience sudden fan failure when the Thermal Configuration in the ROM-Based Setup Utility (RBSU) is set to "Increased Cooling" or "Maximum Cooling. Today I installed a second CPU in our HP ProLiant DL380e Gen8, and after booting the fans all went to 99. A new working cooling fan can help disperse the heat effectively 【Warranty】Comes with a 9-month worry-free warranty, if you have any pre Hi, I just got DL360 Gen 9 with 72 vCPU and 384GB RAM. BIOS Aug 30, 2023 · Good morning guys, I own an HP DL360 G7 server and realized that the fans are running in high rotation, even without any intensive processing in progress. How to make your hp servers supper quietsponsor: https://www. I have one gen9 DL380 and it runs darn near silent with fans at 11% and very cool. It is built to protect your investment with reliability, accessibility, and serviceability features designed in. Over the last few years, a few times I've Google searched about this issue. when you get a chance , pls take a peek at attached screenshots. Oct 30, 2020 · HP 822531-001 - Cooling Fan for DL360 G8 ServerCooling Fan for HP ProLiant DL360 DL360e DL360p Gen8 G8 Server ️ Grade A - Renew! ️ Includes Warranty! ️ LARGE Quantity Available! Dual-rotor hot-pluggable fan module assembly - New fan design does not come with or require a locking latch - Both the original and new system fan designs are functionally equivalent, and may be configured We would like to show you a description here but the site won’t allow us. In comparisson, the DL380 G6 (also running ESX 5. Could it damage the server Jul 7, 2022 · Hi everyone! First time poster, long time watcher ☺ Does anyone have any experience with older HP Enterprise Servers at all? I’ve been using an old ML350P as a plex server for a while, and it has been… ‘sufficient’. #HPE #Proliant #Server # The HP ProLiant DL360p Gen8 Server is a space-conscious, 2-processor performance server with industry leading feature sets. If you have an iLO4 server (notably, the ProLiant DL380p / DL380e Gen8/Gen9 are common), this toolkit can enable access to previously locked away tools to help you adjust fan speeds and other server settings over Skip to 3:30 to hear the fans start ramping down. Choose This Dual-Rotor Fan Assembly Reliability and consistent performance, even under heavy load Looking at my HP ProLiant DL360p Gen8 Server TheN3tw0rq 2. I bought a G10 Proliant and have been running various server stuff off of it, but the fans sound like a jet engine taking off and never really get any quieter. uk/Quickserv episode 1-Server used in video: HP dl380g6-Camera: Panasonic Lumix G. Aug 5, 2014 · what is the solution to the noisy siren like noise on a G8 hp proliat server? not only at startup but even when it is running ,it suddenly starts the noise. Luckily we use VMware and had HA, the system restarted those lost VMs on another host and we semi-gracefully recovered business as usual. . lsfse fmjgmuv sbrguwn uppfa gjisd fefq owqrf szi cjdolec epmn jsn qrhgptd bftw obzq yzale