Home assistant utility meter paused

Home assistant utility meter paused. In net mode when the reservoir is refilled, the delta of the sensor gets rolled back into the Home Assistant will need to know the amount of water that is being consumed to be able to track usage. Perfect. I think this should be implemented. So I want from 1 May to 31 October the changes to happen on 23:00 and on 07:00 and from 1 November to 30 April changes to happen on 02:00 , 08:00 , 15:30 and 17:30. Here you use the sensor from the last step; sensor. unique_id: "iutjrehoinwveyvweotow457tuthu". unit_of_measurement: kWh. The above example will reset on Sunday at 00:00 hours. electricity_secret: 'XXXXX'. utility_meter: giorno_produzione_solare_immessa_in_casa: source: sensor. energy last hour). Energy dashboard: 11:00 -> 12:00 = 4,34 kWh. yaml: utility_meter: water_daily: source: sensor. Sep 3, 2021 · tom_l September 3, 2021, 12:09pm 3. select_tariff Jul 14, 2022 · The integration sensor is amazing and helpful, although it lacks of a reset service (even better, a reset to a user specified value). 9 and you need the state class total_increasing, not measurement. What needs to be done to get the Utility Meter sensors to Jan 23, 2023 · 2. " utility_meter: weekly_energy: source: sensor. See the croniter library. I have attempted to work around the problem with the following sensor template Mar 10, 2020 · Please note that “sensor. This shows under the Sources display, the amount of energy used and the cost incurred for the day. I stumbled on to Ultility Meter which seems good, however my tarriff options aren’t as straight forward as peak or offpeak. Resets are done at 00h00m00s but depend on the HA scheduler which is not realtime. Aug 24, 2021 · Hello smart people, I’ve a stupid samsung washing machine, connected through the SmartThings integrations. The new UI config flow for Utility Meter is not mentioning that a restart of home assistant is needed to activate the sensor. Home Assistant Aug 27, 2021 · go to setting > dashboards > energy. surgelatore_e_lavatrice_power name: consumo_surgelatore_e_lavatrice round: 2 method: left #device_class: energy #unit_of_measurement: W #unit_prefix: k #unit_time: h - platform: integration Jan 17, 2020 · I have experienced this problem with “blips” on a HA restart (my sensor is a NodeMCU with a Tasmota Counter linked to an optical sensor reading electricity meter LED pulses). select_tariff data: entity_id: - utility_meter. sensors: energy_consumption: friendly_name: "Total energy consumption". sensor: - platform: loopenergy. Depending on your setup, the required hardware is provided by your public water utility company, or you may need to buy your own. Sep 5, 2021 · There’s an existing thread elsewhere discussing how to read AMR-capable gas/water/electric meters (using an SDR). wifi drops from the meter, which can be seen to happen 4 times here: …the utility_meter sees that as a reset, and when the meter came back, the value was adding each time. 2 Likes. But utility meter requires a sensor which a counter is not. 3 during an update of HA to version 104. But once you restart HA it loads the last attributes from the database and last Dec 2, 2020 · Hi, I’m using the myenedis integration from HACS in order to replace the Linky integration. I want to get the daily value using the utility meter in order to have the values for each day (and put everything in a graph) using recorder. Learn how to add information about your electricity grid to Home Assistant home energy management. If you don’t have an energy sensor then you need to integrate your power to energy by using the Riemann sum helper: Home Assistant. Also, the utility_meter has some bugs i believe, which Nov 1, 2022 · WallyR (Wally) November 2, 2022, 2:27pm 5. 3 $/kWh. Dec 25, 2023 · The utility meter does not integrate power to energy, it just counts up the total of an energy sensor for a defined cycle (e. It follows common crontab syntax but extended to support more advanced scheduling. services_area_hot_water_energy”. I’d like to use utility meters in order to count dalty, weekly, etc. Personally I keep all the long historical records in an influxDB and plot them using graphana. calibrate service , but that value then does not grow further. 15 until you reach 1400, then the last 100 of the 1500 is calculated at 0. Does that mean these are not enough? utility_meter: daily_energy: source: sensor. Setting up energy monitoring in Home Assistant has brought real-time insight. But I dont get the same information in Shelly and in HA I´m using the Shelly Integration " Shelly smart home platform for HASS and HASSIO" Exempel Feb 9, 2019 · If you extract the last period using a sensor template, then that sensor template becomes your history, since it only gets update once each cycle. Now the utility values are corrected, I divided the values of the cloud API by 1000. state_characteristic: change. I’ve had the configuration running for around a day now but I’m not seeing it on the Energy Dashboard. I’ve tried adding some data to one of the sensors via the utility_meter. yaml… but I want an easy way to change the values in the future… I thought of using a input_number helper as a variable to change the Nov 5, 2023 · A. monthly_home_energy_corrected for any purpose. 2 KB. I’m trying to measure my daily gas usage by using the sensor. This should work for every cycle except January. This was working well as I simply used the total_consumption sensor to create Daily/Weekly/Monthly utility meters. On HA restart parse last_reset as a datetime object dgomes/home-assistant. Thxs for answering. Dec 31, 2023 · utility meters create in UI (helper) are shown and usable immediately (as expected) utility meters from a custom component (I think it’s a Solaredge addon/integration), defined in yamls, included via; homeassistant: packages: !include_dir_named packages → OK (shown as entities and usable) MY new utility meters like this one Nov 6, 2022 · Hi everyone! I’m currently putting some beginners work into Home Assistant and its Energy dashboard. My electric provider has a list of rates that change by the amount of Mar 1, 2020 · To convert this to liters per day, the utility meter can be used. rvdbreemen (Robert van den Breemen) May 5, 2022, 11:35pm 1. First of all you need to gave the utility meter defined in your config. accumulated_wattage_device_a. 12:00 -> 13:00 = 4,12 kWh. I have tried a different browser to see if it is related to my browser. Jul 12, 2020 · I have a Shelly EM with the two CT clamps, one connected to the house mains, and the other connected to the solar-pv Inverter. Unfortunately it is not trivial in my case to read out the energy meter automatically (multi-tenant home, meter is in the basement). 1). 751×321 15. Jan 14, 2023 · Hi all! I have a meter installed on my ASHP and recently discovered I can track usage depending if the ASHP is heating hot water (DHW) (default) or heating the home. The most important for me is have energy consumption reporting I use Shell devices to get that information, I have also added Utility meter in the HA configuration, or at least tried to. My other option is to use a custom:template-entity-row and just change the display in the card. Under Electricity grid you can now edit you Grid Consumption sensor and check use an entity with. You can call it from a button in the frontend. I created a Utility-Meter in helpers for my energy-consumption. Over the day the gas consumption can only be 0,50m3 of usage. They jumped from 1485 to 619. I’m on the most recent (88. The integration created 9 entities, out of which, none are realy usable, let me explain: My washing machine’s name is “Lave-linge” so the entities are switch. i have got Apr 23, 2021 · The utility meter takes an always increasing value and gives you the amount that value has increased over the specified cycle. Screenshot 2023-03-24 at 16-57-42 Developer Tools – Home Assistant 958×319 36. When I set-up a Utility Meter, I create one for my Peak tariff and one for my Off-Peak, and set the rates up in the Energy dashboard. electricity: electricity_serial: 'XXXXX'. Jul 13, 2022 · In experimenting with an SDR, I stumbled upon broadcasts from my utility meters and successfully integrated them with Home Assistant. I have set up cheap and peak rate sensors using the utility meter integration UI. So, for example, you can make a daily energy meter from a sensor that always increases. energy. The former works, but the latter two seems to be off. Constraints: To improve performance for long reporting periods - only Feb 19, 2019 · ok think i figured it out…was missing “data” - alias: Change Utility Tariffs on Weekends trigger: - platform: time at: '15:00:00' - platform: time at: '19:00:00' condition: - condition: 'time' weekday: - sat - sun action: - service: utility_meter. I’m using a utility meter for that. I have had a modbus integration of solaredge failing on me. The problem After a utility meter sensor is reset on the schedule, the last_reset is a date object. water_per_second. Apr 12, 2023 · I have the same problem but can not fix it. Add the following code to configuration. shellyem_5e26f6_channel_1_energy. Mar 5, 2021 · sd_dracula March 5, 2021, 11:08am 6. 0. Create a ‘statistics’ card on your dashboard and graph that entity’s daily or monthly data. Your template sensors reset daily. The graphs and data below show how my daily usage surged from 55. Then just follow the example from documentation of mini-grap-card. It almost works. name: "Cooking Coffee Consumed yearly". entity_id: sensor. You are able to select only the input sensor. Sep 12, 2021 · Good Morning all, Is it possible to use a Utility Meter entity as a source for Power Consumption in the new Energy Panel? The reason for this is that I have a Shelly 3EM clamped over the 3 phases of a home’s Distribution Board. when my solar array is generating more power than my house consumes, i export that exess to the grid. A few weeks ago we changed to daylight saving and since then all of the Utility Meter sensors are resetting at 2300. tesla_charge_energy_added_kahless cycle: monthly value changes from mqtt: UI display: It shows the utility_meter only calculates the difference Apr 8, 2024 · Restart Home assistant. vingerha April 14, 2023, 5:21am 8. You should not have to specify the state class for the utility meter. — RFC for Utility Meter Reports in Home Assistant — Purpose of this change request - to show bar chart or text values in lovelace panel with sensor values aggregated by period (i. I’m not able to create a Riemann sum and related utility meter. I suggest you consider doing this: Create a History Stats sensor that reports the current day’s total heating time. energy_total. Ok, so I just enabled the new utility meter for my dutch smart meter. To use the Utility Meter I had to add this template sensor to record only the hourly energy consumption: sensors: util_meter: friendly_name: 'Hourly Utility Meter' unit_of_measurement: 'kWh' …. Thus you can only use daily or hourly cycles, not weekly. I set two tariffs (Peak and Off-Peak). Now i want to create a automation for the drop down selecter. Your fireplace is burning 0 to 30,000 btu/hr. (See ?, line ?). I’ve checked the system time and it shows that I am UTC+11:00 and AEDT (Australian Eastern Daylight Time) which is correct and the date and time are both right. I’ve set up my smart meter (delivering only the total value every two seconds) and the dashboard puts out the consumption by the hour - fine. Summary. The utility meter sees this sensor’s changes as a negative value, and it will only register negative changes if you switch it to a net consumption mode. I’m trying to figure out how to use an entity to provide the current cost per kWh. All calculations are event driven and triggered by the source, if the last value is sent by the source sensor at 11h59 then its at that time the utility_meter update. The cloud API has a factor 1000 scaling, to Wh, instead of kWh. My fix was going into the developer tools tab and the Statistics page. 8 KB. utility_meter: energy_daily: source: sensor. The energy price is 0. I did not figure out how to edit such kind of helper. Then only feed the energy sensor to utility meter (s) if you want hour/day/month totals outside the energy dashboard. So until I find a solution, I would like to be my own sensor 😁 and read the total value of the meter manually in irregular intervals and enter it together with the time into home May 22, 2021 · Hello everyone, I would like to setup Utility Meter to monitor all consumers in my home. hour, day, month, quarter, year) in past. My configuration is: - platform: integration source: sensor. Successfully merging a pull request may close this issue. e. tesla_card_produzione_solare_immessa_in_casa. So use sensor. I want the yearly part to reset at march 23rd for Dec 3, 2021 · I’m comparing the energy dashboard towards the history of the accumulated_energy_hourly utility and as you can see its off by a few: I completed the config’s and sensors/utility was online before 11:00 - so the measurements should be good hour to hour. I have setup the Utility Meter in HA, which is tracking both daily and Jun 26, 2022 · Is there a way to change the utility meters offset day programatically without going in code… Created a utility meter using the devices helper menu but once created I dont see the setting to change the offset day… so I created the meter in configuration. by the minute or even by the second in the Jan 13, 2021 · Hello! New to Home Assistant and really loves the solution. sticilface (Andrew) November 5, 2023, 7:50pm 3. Solution is very simple - open your utility meter from Helpers - hit Settings - Display precision. 1KWh) sensor. This is much easier for me than dealing with db itself. Added the lambda to the filter section of the pulse counter, to have only one sensor in HA wich is the total m³ consumed, since it is that value that is needed by the utility meter sensor. The Utility Meter integration is used to measure accumulating values like energy, gas, water, heating and more. plasma_energy_power cycle: daily weekly_energy: source: sensor. Feb 16, 2019 · While I have a workaround, it would be more convenient for users to have a “Last Period” state instead of or in addition to an attribute. @home-assistant reopen Reopen the issue. consumption. Since 2021. Unless the utility meter requires an entity in the sensor domain. Several water metering (fluid flow rate sensor device) hardware options are available to do this. Jun 28, 2022 · The sensor itself is a utility meter based on a counter which is increased using some automations. Aug 23, 2019 · Finally found a solution by myself. Than this energy sensor is used to calculate daily/hourly consumption using the [ Utility Meter - Home Assistant ] (utility meter) integration. My goal is to see instantaneous usage but especially daily and monthly totals. The times of „peak“ ar following: Mo-Fri: 07:00AM till 08:00PM Saturday: 07:00AM till 01:00PM „Off-Peak“ times Dec 5, 2023 · I’d like to have a utility meter per user and then based on an other sensor‘s state (i. Sep 14, 2022 · Hello, I have a counter that every tick represents one 1L off consumed water. Aug 27, 2021 · go to setting > dashboards > energy. Use the Riemann Sum integration to convert power to energy. I’m running into an odd issue where I can use your help. But that doesnt seems to be measured by the utility meter. That is just the original sensor you are feeding the utility meter. One is select_tariff and two separate ones for the Day_rate (kWh) and Night_rate (kWh). robb1 (Robert Brown) February 21, 2024, 2:53am 2. Phil89a (Phil89a) November 28, 2023, 8:17pm 1. However things went a bit strange when trying to Dec 26, 2023 · Power (W) from various Shelly PMs → Riemann Integral Helper for continuous energy (kWh) → Utility Meters for hourly, daily, weekly, monthly and yearly energy consumption (kWh). ARafaelSF July 26, 2021, 2:07pm 3. 1557×253 36. If I understand the Utility Meter documentation correctly, then I would need to turn off the “Periodically resetting” option because the source (Riemann Integral Apr 1, 2022 · I have updated to the latest available Home Assistant version. I have created automation. So final config if it can help others : - platform: pulse_counter. daily_energy - utility_meter. current price then use “Ameren810 Current kWh Rate”. tesla_charge_energy_added_kahless, and I want show my charge energe from daily, monthly and yearly. plasma_energy_power cycle: monthly yearly_energy: source: sensor. Jan 13, 2022 · I calibrated the utility_meter to zero, and it started accumulating the daily statistics. monthly_home energy” is the utiliity_meter, and the “float - 1250” is the correction which is subtract 1250 kWh from the utility_meter value. The sensor I added from MQTT is incrementing properly with the power company’s meter reading, but it’s not counting on the HomeAssistant “utility meter” sensor. water_daily” will be added to Home Assistant, which can be added to Lovelace. I am looking for a way to specify when the yearly utility meter cycle should reset. Now, my first test was simply utility_meter: daily_energy: source: sensor. Oct 5, 2019 · Currently the utility_meter’s are treated “like” sensors, yet they do not support the friendly_name attribute… This is very frustrating when you try to set up things that auto fill (monster cards for eg)… because they report a horrid looking name … Sep 22, 2022 · I am reading from a level sensor in a reservoir with a slowly declining value that is occasionally reset when the reservoir is refilled. I had expected the state to ‘catch up’ since the source sensor was accumalating energy useage whilst the HA Mar 7, 2023 · It’s really going to depend on your definition of easy. There’s one post in it where the user’s meter provided no information because the gas utility has means of “wakening” the meter exclusively for their own use of reading the meter and then suspending it until the next time they pass through to read it. While this easily gives you nice daily and monthly unified overviews the power consumption of your smart plugs it doesn’t allow you to query other time frames or drill down by device, without exposing the stats for each sensor manually. The energy meter does not take meter readings (total kWh since Jan 13, 2021 · Aside from my monthly utility bill, understanding my home’s energy consumption has always been fairly opaque. Here’s my YAML: sensor: - platform: mqtt. Feb 18, 2024 · The following code gives the result in WattHours. 3 btu/hr. 3. You need to be using Home Assistant 2021. utility_meter: daily_import_energy: source: sensor. But as I’d like to get more detailed statistics, p. @home-assistant unassign utility_meter Removes the current integration label and assignees on the issue, add the integration domain after Feb 11, 2019 · The integration sensor that takes kW readings every few seconds from my Loop energy monitor (a clamp meter on the live feed into my house) is showing 41kWh as is the loop dashboard. - platform: history_stats name: ULkohuone entity_id: switch. So I've been fiddling around with the utility_meter and integration platform for a few rooms but my babyroom doesn't seen to collect any data. Hi there! New HA user here and loving all the tinkering so far. Hi, thanks for making Utility Meter configurable via UI (helpers section). accumulated_kW_per_hour_device_A Unit of measurement: kWh Aug 29, 2019 · Hey guys Is it possible to count how many days elapsed after the Utility meter resets, and then keep counting until it reaches 60 days? After that, I’d like to reset the counter again to zero… Sep 2, 2021 · I’ve been using Shelly 3EM with more or less success together with utility_meter now for several month. ulkohuone state: "on" type: time start: " { { today_at () }}" end: " { { now () }}" Create Utility Meter sensors that report Nov 24, 2020 · I’m not sure what’s going on but I can’t get my utility meter to work. As an example, I have a variable titled “sensor. The energy_used sensor it’s based on is an increasing measurement, it’s never reset. Jun 4, 2021 · Hello I have implemented the bellow utility meters. I’ve added the configuration to get a daily/monthly/yearly sensor for the total usage but i can’t get it to work for those smart plugs. The utility meter states that it is paused. The docs list the option for days, which works for monthly resets at a specific day. the connection of the users phone to the WiFi of the car) start/stop the counting. name: "kWh Used Last 60min". tom_l July 26, 2021, 1:50pm 2. The energy dashboard needs to see the device actively reporting values for some time in order to be able to add it to the dashboard. thanks, this works! 1 Like. BUT when the meter drops to unavailable, e. So they will only always increase over a cycle of a day or less. Both are utility meter values from sensor. With this, I have a sensor with all the different informations like before. reset. And the final result looks like. Create a utility sensor in Settings\Devices & Services\Helpers\Create helper\Utility sensor. cycle: daily. Thanks. Jul 26, 2023 · I’m looking to add my electric usage and cost to my home assistant system, seems I can’t copy the data from the energy dashboard in home assistant. The energy dashboard does not offer either of these sensors in Aug 6, 2021 · Enter your reading into an input_number. Jun 1, 2020 · Hi, I am using Shelly 3EM through MQTT, and finally I have used following code to clear out the problem of getting unavalaible / unknown state of total power meter converted to 0 on restart: sensor: - platform: template. Apr 10, 2022 · I have been trying to find a way to correct the glitch of dsmr values that cause the utility meter. In my country we use 3, peak time, day time and night time. You can apply a cycle to make it reset whenever you want. 3 participants. lave_linge (a switch) sensor. . Please check the docs at https://home-assistant. The relevant bit of my HA config is below. Hourly; This will result in; sensor. And I used kWh, instead of Wh. New value from source sensor: 23558 (kWh) → OK PASS → 23558 stored as new total in HA utility meter Jun 17, 2023 · Code owners of utility_meter can trigger bot actions by commenting: @home-assistant close Closes the issue. Feb 28, 2024 · Seems a simple thing to do in hardware, set up a counter that increments through each day, then resets at midnight, but it seems a lot harder than that as code. Jan 28, 2022 · For natural gas 1 therm = 100 cu ft of distribution line quality gas (majority of liquids processed out). @home-assistant unassign utility_meter Removes the current integration label and assignees on the issue, add the integration domain after Jul 21, 2023 · I have a sensor named sensor. This gives you power. Gas is sold by MMBTU (million btu) in the US (NYMEX and henry hub). I have read through this post and other related ones to see if I’ve missed something but to no avail. After a restart of Home Assistant, the entity “sensor. With that URL you could create a Home Assistant RESTful sensor to get the data. Nov 28, 2023 · Configuration Frontend. Every tariff you define gets its Dec 23, 2023 · Hello, i would like to setup an utility meter on package with following setup which works if set on HA UI. In which case, use a template sensor to read your input number and feed the utility meter with the template sensor. If I understand it correctly, the utility_meter will reset at midnight on new year’s eve. Aug 22, 2023 · I have a statistics sensor that shows my energy usage over the last 60min - it’s configured like this: - platform: statistics. Feb 9, 2019 · If you extract the last period using a sensor template, then that sensor template becomes your history, since it only gets update once each cycle. mekaneck (Rick Auch) November 5, 2023, 7:05pm 2. If that does not fix it try renaming the utility meter, utility_meter: Feb 18, 2024 · The following code gives the result in WattHours. Last reset is no longer a valid attribute. Utility_meter status paused. This showed that there were statistic errors on two of the meters caused by a switch from Aug 8, 2023 · It provides an advanced method of defining when should the counter be reset. energy_used. Sometimes, we want to integrate only over a certain period of time or maybe reset every 6 hours or maybe not at specific intervals but when certain events occur. Here’s my situation: Rainforest Eagle gateway sending instantaneous wattage consumption every few seconds using Jan 19, 2022 · Hi all, i’ve got multiple zigbee 3. Have I missed something with the configuration here? Here is the config entry for the meter: utility_meter: energy: name Sep 1, 2022 · Last value in HA utility_meter: 23556 (kWh) - a maximum increase of 5 kWh is allowed, either from the last stored value in HAs utility_meter or last received vs new value from device. Djal March 8, 2021, 9:22pm 20. Nov 7, 2022 · I have three utility meters tracking HVAC on-time for fan, heat, and cool. plasma_energy_power cycle: yearly But Jul 26, 2021 · cycle: never. Any one have a explanation for this? Jan 19, 2022 · Hi All, I’ve a bunch of tuya plugs with energy monitor and them works fine. lave_linge_deltaenergy (fluctuating between 0 and 0. Oct 11, 2022 · Hi there Im an absolutely newbie on HomeAssistant, i set up my Shelly 3EM in Home Assistant, and it works great. Aug 11, 2022 · Except for the grouped energy sensors, powercalc just sums all of the individual energy sensors to calculate the group state. The utility meter should have statistics data retained indefinitely. @home-assistant rename Awesome new title Renames the issue. I have cleared the cache of my browser. lave_linge Apr 11, 2022 · If you have a Utility Meter helper and you try to modify the cron pattern for example you can not do this. tariffs: Sep 1, 2023 · Use a template sensor to multiply the current by the voltage. My electric provider has a list of rates that change by the amount of May 22, 2020 · maxwroc (Maks) March 6, 2021, 1:02pm 19. monthly_energy tariff: peak - service: utility_meter. 1 earlier today. energy_export_sum which is also shown. Aug 26, 2022 · Above 1400 it is calculated at 0. So your Heater is burning 85,714. This created 3 entities (+2 invisible ones). The utility_meter is relatively new, and the docs aren’t completely clear. Mar 7, 2020 · I’ve built a bandwidth monitor based on this and this post. That is just the contents of a Modbus register, and increments every 5 seconds with the latest value Aug 8, 2023 · It provides an advanced method of defining when should the counter be reset. plasma_energy_power cycle: weekly monthly_energy: source: sensor. This i can see by the amount of “negative” kW, kWh, on the CT clamp on the house mains. io/components/utility_meter/ Dec 3, 2019 · Next steps. The utility meters do not have to use or know anything about the power Mar 24, 2023 · However, there is now a disparity of aroud 100W (consistent with the use over that half hour) between utility meter and the esphome source sensor. Therms from most gas utilities. So far, so good. Use the input number as the input to a utility meter. 9 you can use a cron expression, therefore supporting this option. 5 KB. In the docs it says to create template sensors to compute daily and monthly total usage. I noticed it says 'status: paused' for this room. It is actually like that. name: Weekly Energy. Nope. Not yearly. I managed to make the sensor template and for me it works since I have the value in Oct 12, 2023 · I have the latest versions of HA installed on a RPi4. The unit is not shown in the statistics but do not know why. I wrote with help of utility meter integration daily and monthly energy consumption and they work flawlessly 🙂 I wonder if I can also make sensors which will show previous month or at least yesterday energy consumption (I can’t see that in utility meter options and I don’t want make any . Feb 11, 2019 · Check: utility_meter->utility_meter->daily_power_offpeak_alt->mode. Here is my config (as a minimal example Nov 24, 2019 · dgomes (Diogo Gomes) September 3, 2021, 1:01am 3. Dec 25, 2020 · Hello, I have pzem-004t v1 connected to wemos D1 mini with esphome on board and it works really good. g. The export Montly has a unit. Example: if my phone connects to the car WiFi “my” utility meter shall start adding the milage which comes from the total milage sensor. tom_l July 26, 2021, 2:12pm 4. An alternative approach which would complement this setup would be to publish your sensor stats Jul 27, 2020 · As the title refers. cycle: yearly. esp_6channel_ct6_rawatthours. and restart again. Then recreate the utility meter by deleting the comments. cooking_coffee_consumed. In Developer Tools/States I found that there are 2 more entities listed that don’t show up in the Settings Aug 5, 2021 · I would really like to use all the new and old energy features of home assistant. Is there a way to do that? Should’nt a counter be considered as a sensor as well? Herebelow is the automation code to increment the counter at every tick - id: 532445d2 Sep 21, 2020 · Development. Due to 3EM reporting ZERO kWh several times a day when the 3EM becomes UNAVAILABLE (no idea why, as it got perfectly fine Wifi connection), I had to make quite complicated templates to sort out those ZERO values and filter them so utility_meter sees a growing number all the time and doesn Jan 24, 2023 · I created a Utility Meter helper with Input Sensor: HomeTotal and Supported Tariffs: Day, Night. Reading briefly through the docs at your link, it looks like there is a way for you to generate a URL you can use to make an API call to get your utility information. You can see the export Daily which has no unit. The heat on-time utility meter was showing statistics but the other two were not after a recent update. jgosnell: The templates look like it is just an over/under type calculation, for instance if I use 1500 kWh the template calculates all 1500 kWh at . cron: "0 0 * * 7". 3 to 77283. Mar 8, 2023 · Example demonstrating how to use them. Sep 16, 2020 · Or if the day changes month to month (due to weekends or whatever) use this service: utility_meter. 0 smart plugs with energy consumption (current usage & total usage). max_age: minutes: 60. May 5, 2022 · Configuration. I want to change tariff on different time between differnet periods of the year. I used the below code which seems ok at first, but I Jan 4, 2024 · Code owners of utility_meter can trigger bot actions by commenting: @home-assistant close Closes the issue. Mar 15, 2021 · I have created utility meter which show so many decimals. pin: D1. Create a utility sensor that accumulates per hour. Then I test it like following code: utility_meter: monthly_charge: name: kahless_tesla_charge_energy_monthly source: sensor. I wasn’t able to find previous posts on the exact setup I’m using. Describe the issue you are experiencing. It will do this for you. Update: Problem miraculously solved itself. Feb 27, 2019 · I’m finally getting some utility information setup in HA, and want to make sure my logic is sound. 234 kwh… So how do I correct the state of the utility sensors (daily, weekly, monthly, yea… May 3, 2021 · Dear community members and developers, please take a look and vote or comment on RFC for Reports. gas_consumption in a utility meter config. 15 per your example. name: "Power Company Meter". No, because if the original sensor reset, or decrease, utility meter can always catch the global sum. hadxb1 (Option 13) September 1, 2023, 11:12am 3. It is configured as: cooking_coffee_consumed_yearly: source: counter. You can also use the tariffs option to create multiple conditional sensors from the one utility meter. unique_id: "power_company Feb 8, 2019 · The utility_meter timings depend of the source. cl sz au id hv ib za gu do io